C-169, Malegaon MIDC, Sinnar, Dist. Nashik, Maharashtra, India, PIN 422113 +91 9503487036 +91 7276906080 almightyindustries1111@gmail.com

Welding & Inspection

Cleaner · Penetrant · Developer

DP Set (CL-90 · PL-91 · DP-92)

Cleaner, penetrant and developer aerosols for liquid penetrant NDT. Reveals surface flaws with a coloured dye.

  • 400 ml
Cleaner · Penetrant · Developer — DP Set (CL-90 · PL-91 · DP-92)

Drag to rotate · pinch or use + / − to zoom

Overview

Cleaner · Penetrant · Developer

The Cleaner-Penetrant-Developer set, also known as the DP Set, is used for liquid penetrant testing, one of the oldest and simplest NDT methods.

It reveals surface discontinuities by bleed-out of a coloured dye from the flaw. The technique is based on the ability of a liquid to be drawn into a clean surface discontinuity by capillary action. After a dwell time (minimum 10 minutes) the excess penetrant is removed and a developer is applied to draw the penetrant trapped in flaws and cracks to the surface, where it becomes visible.

Advantages

Advantages

01

Highly sensitive

Even small discontinuities can be detected.

02

Works on many materials

Metallic and non-metallic, magnetic and non-magnetic, conductive and non-conductive materials can be inspected.

03

Rapid inspection

Large areas and volumes can be inspected quickly.

04

Complex shapes

Suitable for parts with complex shapes.

05

Visible indications

Indications are produced directly on the surface of the part and can be observed visually, by the naked eye.

06

Portable

Available in aerosol spray cans, so it can be carried anywhere.

07

Low cost

Materials and associated equipment are not expensive.

Applications

Where it works.

  • Non-destructive testing (NDT)
  • Surface flaw and crack detection

How the method works

How the method works

  1. 01

    Liquid penetrant testing is one of the oldest and simplest NDT methods.

  2. 02

    It is used to reveal surface discontinuities by bleed-out of a coloured dye from the flaw.

  3. 03

    The technique is based on the ability of a liquid to be drawn into a clean surface discontinuity by capillary action.

  4. 04

    After a period (dwell time, minimum 10 minutes) the excess penetrant is removed and a developer is applied to draw the penetrant trapped in flaws and cracks to the surface, where it will be visible.

Packaging & specifications

Available packing.

400ml
Carton
25 nos
Master carton
50 nos

Technical information

CleanerCL-90
PenetrantPL-91
DeveloperDP-92
Minimum dwell time10 minutes
MethodLiquid penetrant testing

Need Cleaner · Penetrant · Developer for your plant or workshop?

Send your requirement, pack size and quantity. Our team will respond with the right product and packing.

almightyindustries1111@gmail.com